Smart home energy storage for solar integration and reliable backup power.

CLN Energy home inverter lithium-ion battery is an advanced energy storage solution that replaces traditional lead-acid batteries. Unlike lead-acid batteries, which are bulky, have shorter lifespans, and need regular maintenance, lithium- ion batteries offer notable advantages. They are more compact, lightweight, and efficient, with higher energy density and longer cycle life. Furthermore, lithium-ion batteries charge and discharge more quickly, providing a reliable and consistent power supply. Homeowners can benefit from improved energy efficiency, lower maintenance costs, and enhanced overall performance in their home energy storage systems.
Inbuilt battery indicator
Deep discharge protection
No fire risk
Bluetooth connectivity
Low battery alarm
Easy installation

CLN Energy home inverter lithium-ion battery is an advanced energy storage solution that replaces traditional lead-acid batteries. Unlike lead-acid batteries, which are bulky, have shorter lifespans, and need regular maintenance, lithium- ion batteries offer notable advantages. They are more compact, lightweight, and efficient, with higher energy density and longer cycle life. Furthermore, lithium-ion batteries charge and discharge more quickly, providing a reliable and consistent power supply. Homeowners can benefit from improved energy efficiency, lower maintenance costs, and enhanced overall performance in their home energy storage systems.
Inbuilt LED indicator
Deep discharge protection
No fire risk
Bluetooth connectivity
Low battery alarm
Easy installation

CLN Energy home inverter lithium-ion battery is an advanced energy storage solution that replaces traditional lead-acid batteries. Unlike lead-acid batteries, which are bulky, have shorter lifespans, and need regular maintenance, lithium- ion batteries offer notable advantages. They are more compact, lightweight, and efficient, with higher energy density and longer cycle life. Furthermore, lithium-ion batteries charge and discharge more quickly, providing a reliable and consistent power supply. Homeowners can benefit from improved energy efficiency, lower maintenance costs, and enhanced overall performance in their home energy storage systems.
Inbuilt battery indicator
Deep discharge protection
No fire risk
Bluetooth connectivity
Low battery alarm
Easy installation

CLN Energy home inverter lithium-ion battery is an advanced energy storage solution that replaces traditional lead-acid batteries. Unlike lead-acid batteries, which are bulky, have shorter lifespans, and need regular maintenance, lithium- ion batteries offer notable advantages. They are more compact, lightweight, and efficient, with higher energy density and longer cycle life. Furthermore, lithium-ion batteries charge and discharge more quickly, providing a reliable and consistent power supply. Homeowners can benefit from improved energy efficiency, lower maintenance costs, and enhanced overall performance in their home energy storage systems.
Inbuilt LED indicator
Deep discharge protection
No fire risk
Bluetooth connectivity
Low battery alarm
Easy installation

CLN Energy home inverter lithium-ion battery is an advanced energy storage solution that replaces traditional lead-acid batteries. Unlike lead-acid batteries, which are bulky, have shorter lifespans, and need regular maintenance, lithium- ion batteries offer notable advantages. They are more compact, lightweight, and efficient, with higher energy density and longer cycle life. Furthermore, lithium-ion batteries charge and discharge more quickly, providing a reliable and consistent power supply. Homeowners can benefit from improved energy efficiency, lower maintenance costs, and enhanced overall performance in their home energy storage systems.

A ground-mounted LiFePO4 battery on an integrated wheeled base, so it moves into place without lifting gear. Smart BMS, LCD display, Bluetooth remote monitoring and a heavy-duty metal casing, with up to 16 units connecting in parallel. Built for home and solar energy storage, commercial and industrial facilities, telecom and data-centre backup, and microgrid projects.

A ground-mounted LiFePO4 battery on an integrated wheeled base, so it moves into place without lifting gear. Smart BMS, LCD display, Bluetooth remote monitoring and a heavy-duty metal casing, with up to 16 units connecting in parallel. Built for home and solar energy storage, commercial and industrial facilities, telecom and data-centre backup, and microgrid projects.

A ground-mounted LiFePO4 battery on an integrated wheeled base, so it moves into place without lifting gear. Smart BMS, LCD display, Bluetooth remote monitoring and a heavy-duty metal casing, with up to 16 units connecting in parallel. Built for home and solar energy storage, commercial and industrial facilities, telecom and data-centre backup, and microgrid projects.

A ground-mounted LiFePO4 battery on an integrated wheeled base, so it moves into place without lifting gear. Smart BMS, LCD display, Bluetooth remote monitoring and a heavy-duty metal casing, with up to 16 units connecting in parallel. Built for home and solar energy storage, commercial and industrial facilities, telecom and data-centre backup, and microgrid projects.

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.
Integrated solution
Life cycle
Superior durability & safety
Installation

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.
Integrated solution
Life cycle
Superior durability & safety
Installation

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.
Integrated solution
Life cycle
Superior durability & safety
Installation

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.
Integrated solution
Life cycle
Superior durability & safety
Installation

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.
Integrated solution
Life cycle
Superior durability & safety
Installation

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.

Hybrid inverter, MPPT solar charger and stackable LiFePO4 battery modules in one tower: 5 kW single-phase output with grid export and 10 kWh of storage. It can be scheduled by time-of-day tariff - charging when grid power is cheapest, running on solar through the day, and discharging at the evening peak.

Hybrid inverter, MPPT solar charger and stackable LiFePO4 battery modules in one tower: 5 kW single-phase output with grid export and 15 kWh of storage. It can be scheduled by time-of-day tariff - charging when grid power is cheapest, running on solar through the day, and discharging at the evening peak.

Hybrid inverter, MPPT solar charger and stackable LiFePO4 battery modules in one tower: 5 kW single-phase output with grid export and 20 kWh of storage. It can be scheduled by time-of-day tariff - charging when grid power is cheapest, running on solar through the day, and discharging at the evening peak.

CLN Energy stackable lithium-ion energy storage system designed for residential backup and solar applications. Supports up to 4 modules (20.48 kWh), with integrated EMS and optional off-grid inverter. Offers multiple operating modes, remote monitoring via app, and advanced protection features. Easy to install, safe, and maintenance-free
Modular and Scalable
Safe and Long-lasting
Smart Energy Management
Remote Monitoring
Advanced Communication
Built-in Battery Protections
Plug-and-Play Design
Wide Temperature Range
Certified Quality
Eco-Friendly Chemistry

CLN Energy stackable lithium-ion energy storage system designed for residential backup and solar applications. Supports up to 4 modules (20.48 kWh), with integrated EMS and optional off-grid inverter. Offers multiple operating modes, remote monitoring via app, and advanced protection features. Easy to install, safe, and maintenance-free
Modular and Scalable
Safe and Long-lasting
Smart Energy Management
Remote Monitoring
Advanced Communication
Built-in Battery Protections
Plug-and-Play Design
Wide Temperature Range
Certified Quality
Eco-Friendly Chemistry

CLN Energy stackable lithium-ion energy storage system designed for residential backup and solar applications. Supports up to 4 modules (20.48 kWh), with integrated EMS and optional off-grid inverter. Offers multiple operating modes, remote monitoring via app, and advanced protection features. Easy to install, safe, and maintenance-free
Modular and Scalable
Safe and Long-lasting
Smart Energy Management
Remote Monitoring
Advanced Communication
Built-in Battery Protections
Plug-and-Play Design
Wide Temperature Range
Certified Quality
Eco-Friendly Chemistry

CLN Energy stackable lithium-ion energy storage system designed for residential backup and solar applications. Supports up to 4 modules (20.48 kWh), with integrated EMS and optional off-grid inverter. Offers multiple operating modes, remote monitoring via app, and advanced protection features. Easy to install, safe, and maintenance-free
Modular and Scalable
Safe and Long-lasting
Smart Energy Management
Remote Monitoring
Advanced Communication
Built-in Battery Protections
Plug-and-Play Design
Wide Temperature Range
Certified Quality
Eco-Friendly Chemistry

COMING SOON

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.
1 MPPT tracker, max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.
1 MPPT tracker, max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.
1 MPPT tracker, max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.
1 MPPT tracker, max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.
1 MPPT tracker, max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.
1 MPPT tracker, max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V
| Parameter | 12.8V 100Ah | 25.6V 100Ah |
|---|---|---|
| Nominal Voltage (V) | 12.8 | 25.6 |
| Capacity (Ah) | 100 | |
| Cell Type and Chemistry | Prismatic (100Ah) and LFP | |
| BMS Type | Smart | |
| Maximum Cut-off Voltage (V) | 14.4 (±0.4) | 28.8 (±0.8) |
| Minimum Cut-off Voltage (V) | 10.0 (±0.4) | 20.0 (±0.8) |
| Charging Voltage (V) | 14 | 28 |
| Recommended Charging Current (A) | 30 | |
| Maximum Charging Current (A) | 50 | |
| Recommended Discharge Current (A) | 50 | |
| Maximum Discharging Current (A) | 100 | |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 3000 | |
| Cell Under Voltage Protection | Yes | |
| Cell Over Voltage Protection | Yes | |
| Over Current Protection | Yes | |
| Short Circuit Protection | Yes | |
| Temperature Protection | Yes | |
| Working Temperature (°C) | 0-60 | |
| Storage Temperature (°C) | 0-45 | |
| Weight (kg) | 17 (approx.) | 25 (approx.) |
| Size (LxWxH)mm | 330x255x180 | 540x255x180 |
| Communication | As per requirement | |
| Connector | Through wall connector | |
| IP Protection | IP20 | |
| Warranty | 5 Years | |
| Parameter | 48V 200Ah (WM) | 51.2V 100Ah (WM) |
|---|---|---|
| Nominal Voltage (V) | 48 | 51.2 |
| Capacity (Ah) | 100 | 100 |
| Cell Type and Chemistry | Prismatic (100Ah) and LFP | Prismatic (100Ah) and LFP |
| BMS Type | Smart | Smart |
| Maximum Cut-off Voltage (V) | 54.0 (±1.5) | 57.6 (±1.5) |
| Minimum Cut-off Voltage (V) | 42 (±1.5) | 44.8 (±1.5) |
| Charging Voltage (V) | 52.5 | 56 |
| Recommended Charging Current (A) | 25 | 25 |
| Rated Discharge Current (A) | 30 | 30 |
| Peak Discharging Current (A) | 100 | 100 |
| Cycle Life @25°C at 90% DOD, 0.5C/1C (Cycles) | 1500 | 1500 |
| Cycle Life @25°C at 90% DOD, 0.5C/0.5C (Cycles) | 2000 | 2000 |
| Cell Under Voltage Protection | Yes | Yes |
| Cell Over Voltage Protection | Yes | Yes |
| Over Current Protection | Yes | Yes |
| Short Circuit Protection | Yes | Yes |
| Temperature Protection | Yes | Yes |
| Ambient Temperature (°C) | 0–60 | 0–60 |
| Storage Temperature (°C) | 10–35 | 10–35 |
| Size (L x W x H) mm | 785×155×505 | 785×155×505 |
| Weight (kg) | 55 (approx.) | 57 (approx.) |
| Power Connector | Through wall | Through wall |
| Communication Connector | As per requirement | As per requirement |
| IP Protection | IP20 | IP20 |
| Parameter | 12.8V 100Ah | 25.6V 100Ah |
|---|---|---|
| Nominal Voltage (V) | 12.8 | 25.6 |
| Capacity (Ah) | 100 | |
| Cell Type and Chemistry | Prismatic (100Ah) and LFP | |
| BMS Type | Smart | |
| Maximum Cut-off Voltage (V) | 14.4 (±0.4) | 28.8 (±0.8) |
| Minimum Cut-off Voltage (V) | 10.0 (±0.4) | 20.0 (±0.8) |
| Charging Voltage (V) | 14 | 28 |
| Recommended Charging Current (A) | 30 | |
| Maximum Charging Current (A) | 50 | |
| Recommended Discharge Current (A) | 50 | |
| Maximum Discharging Current (A) | 100 | |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 3000 | |
| Cell Under Voltage Protection | Yes | |
| Cell Over Voltage Protection | Yes | |
| Over Current Protection | Yes | |
| Short Circuit Protection | Yes | |
| Temperature Protection | Yes | |
| Working Temperature (°C) | 0-60 | |
| Storage Temperature (°C) | 0-45 | |
| Weight (kg) | 17 (approx.) | 25 (approx.) |
| Size (LxWxH)mm | 330x255x180 | 540x255x180 |
| Communication | As per requirement | |
| Connector | Through wall connector | |
| IP Protection | IP20 | |
| Warranty | 5 Years | |
| Parameter | 25.6V 200Ah | 51.2V 100Ah |
|---|---|---|
| Nominal Energy (kWh) | 5.12 | 5.12 |
| Nominal Voltage (V) | 25.6 | 51.2 |
| Capacity (Ah) | 200 | 100 |
| Cell Type and Chemistry | Prismatic, LFP | |
| BMS Type | Smart | |
| Maximum cut-off voltage (V) | 28.8 (±0.8) | 57.6 (±1.5) |
| Minimum cut-off voltage (V) | 20.0 (±0.8) | 44.8 (±1.5) |
| Charging Voltage (V) | 28 | 56 |
| Recommended Charging Current (A) | 30 | |
| Maximum Charging Current (A) | 50 | |
| Recommended Discharge Current (A) | 50 | |
| Maximum Discharging Current (A) | 100 | |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | |
| Protection | BMS, MCB | |
| Cell under voltage protection | Yes | |
| Cell over voltage Protection | Yes | |
| Over current protection | Yes | |
| Short circuit protection | Yes | |
| Temperature protection | Yes | |
| Working Temperature (°C) | 0 – 60 | |
| Storage Temperature (°C) | 0 – 45 | |
| Weight (kg) | 55(approx.) | 57(approx.) |
| Size (LxWxH)mm | 653x400x183 | 653x400x183 |
| Communication | RS485 | |
| Connector | Through Wall Connector | |
| IP Protection | IP 20 | |
| Scalability | Up to 16 units in parallel | |
| Display | LCD Display | |
| Warranty | 5 Years | |
| Installation Type | Wall Mount | |
| Parameter | 25.6V 200Ah | 51.2V 100Ah |
|---|---|---|
| Nominal Energy (kWh) | 5.12 | 5.12 |
| Nominal Voltage (V) | 25.6 | 51.2 |
| Capacity (Ah) | 200 | 100 |
| Cell Type and Chemistry | Prismatic, LFP | |
| BMS Type | Smart | |
| Maximum cut-off voltage (V) | 28.8 (±0.8) | 57.6 (±1.5) |
| Minimum cut-off voltage (V) | 20.0 (±0.8) | 44.8 (±1.5) |
| Charging Voltage (V) | 28 | 56 |
| Recommended Charging Current (A) | 30 | |
| Maximum Charging Current (A) | 50 | |
| Recommended Discharge Current (A) | 50 | |
| Maximum Discharging Current (A) | 100 | |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | |
| Protection | BMS, MCB | |
| Cell under voltage protection | Yes | |
| Cell over voltage Protection | Yes | |
| Over current protection | Yes | |
| Short circuit protection | Yes | |
| Temperature protection | Yes | |
| Working Temperature (°C) | 0 – 60 | |
| Storage Temperature (°C) | 0 – 45 | |
| Weight (kg) | 55(approx.) | 57(approx.) |
| Size (LxWxH)mm | 653x400x183 | 653x400x183 |
| Communication | RS485 | |
| Connector | Through Wall Connector | |
| IP Protection | IP 20 | |
| Scalability | Up to 16 units in parallel | |
| Display | LCD Display | |
| Warranty | 5 Years | |
| Installation Type | Wall Mount | |
| Parameter | 25.6V 230Ah | 25.6V 314Ah | 51.2V 230Ah | 51.2V 314Ah |
|---|---|---|---|---|
| Nominal Energy (kWh) | 5.8 | 8 | 11.7 | 16 |
| Nominal Voltage (V) | 25.6 | 51.2 | ||
| Capacity (Ah) | 230 | 314 | 230 | 314 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 28.8 (±0.8) | 57.6 (±1.5) | ||
| Minimum cut-off voltage (V) | 20.0 (±0.8) | 44.8 (±1.5) | ||
| Charging Voltage (V) | 28 | 56 | ||
| Recommended Charging Current (A) | 70 | 90 | 70 | 90 |
| Maximum Charging Current (A) | 100 | 100 | 100 | 100 |
| Recommended Discharge Current (A) | 100 | 100 | 100 | 100 |
| Maximum Discharging Current (A) | 150 | 150 | 150 | 150 |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | |||
| Protection | BMS/MCB | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 – 60 | |||
| Storage Temperature (°C) | 0 – 45 | |||
| Weight (kg) | 53 | 60 | 91 | 121 |
| Size (LxWxH)mm | 540x375x261 | 400x475x269 | 683x450x258 | 895x450x235 |
| Communication | RS485 | |||
| Connector | Through Wall Connector | |||
| IP Protection | IP20 | |||
| Scalability | Up to 16 units in parallel | |||
| Display | LCD Display | |||
| Warranty | 5 Years | |||
| Installation Type | Ground Mount | |||
| Parameter | 25.6V 230Ah | 25.6V 314Ah | 51.2V 230Ah | 51.2V 314Ah |
|---|---|---|---|---|
| Nominal Energy (kWh) | 5.8 | 8 | 11.7 | 16 |
| Nominal Voltage (V) | 25.6 | 51.2 | ||
| Capacity (Ah) | 230 | 314 | 230 | 314 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 28.8 (±0.8) | 57.6 (±1.5) | ||
| Minimum cut-off voltage (V) | 20.0 (±0.8) | 44.8 (±1.5) | ||
| Charging Voltage (V) | 28 | 56 | ||
| Recommended Charging Current (A) | 70 | 90 | 70 | 90 |
| Maximum Charging Current (A) | 100 | 100 | 100 | 100 |
| Recommended Discharge Current (A) | 100 | 100 | 100 | 100 |
| Maximum Discharging Current (A) | 150 | 150 | 150 | 150 |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | |||
| Protection | BMS/MCB | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 – 60 | |||
| Storage Temperature (°C) | 0 – 45 | |||
| Weight (kg) | 53 | 60 | 91 | 121 |
| Size (LxWxH)mm | 540x375x261 | 400x475x269 | 683x450x258 | 895x450x235 |
| Communication | RS485 | |||
| Connector | Through Wall Connector | |||
| IP Protection | IP20 | |||
| Scalability | Up to 16 units in parallel | |||
| Display | LCD Display | |||
| Warranty | 5 Years | |||
| Installation Type | Ground Mount | |||
| Parameter | 25.6V 230Ah | 25.6V 314Ah | 51.2V 230Ah | 51.2V 314Ah |
|---|---|---|---|---|
| Nominal Energy (kWh) | 5.8 | 8 | 11.7 | 16 |
| Nominal Voltage (V) | 25.6 | 51.2 | ||
| Capacity (Ah) | 230 | 314 | 230 | 314 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 28.8 (±0.8) | 57.6 (±1.5) | ||
| Minimum cut-off voltage (V) | 20.0 (±0.8) | 44.8 (±1.5) | ||
| Charging Voltage (V) | 28 | 56 | ||
| Recommended Charging Current (A) | 70 | 90 | 70 | 90 |
| Maximum Charging Current (A) | 100 | 100 | 100 | 100 |
| Recommended Discharge Current (A) | 100 | 100 | 100 | 100 |
| Maximum Discharging Current (A) | 150 | 150 | 150 | 150 |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | |||
| Protection | BMS/MCB | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 – 60 | |||
| Storage Temperature (°C) | 0 – 45 | |||
| Weight (kg) | 53 | 60 | 91 | 121 |
| Size (LxWxH)mm | 540x375x261 | 400x475x269 | 683x450x258 | 895x450x235 |
| Communication | RS485 | |||
| Connector | Through Wall Connector | |||
| IP Protection | IP20 | |||
| Scalability | Up to 16 units in parallel | |||
| Display | LCD Display | |||
| Warranty | 5 Years | |||
| Installation Type | Ground Mount | |||
| Parameter | 25.6V 230Ah | 25.6V 314Ah | 51.2V 230Ah | 51.2V 314Ah |
|---|---|---|---|---|
| Nominal Energy (kWh) | 5.8 | 8 | 11.7 | 16 |
| Nominal Voltage (V) | 25.6 | 51.2 | ||
| Capacity (Ah) | 230 | 314 | 230 | 314 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 28.8 (±0.8) | 57.6 (±1.5) | ||
| Minimum cut-off voltage (V) | 20.0 (±0.8) | 44.8 (±1.5) | ||
| Charging Voltage (V) | 28 | 56 | ||
| Recommended Charging Current (A) | 70 | 90 | 70 | 90 |
| Maximum Charging Current (A) | 100 | 100 | 100 | 100 |
| Recommended Discharge Current (A) | 100 | 100 | 100 | 100 |
| Maximum Discharging Current (A) | 150 | 150 | 150 | 150 |
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | |||
| Protection | BMS/MCB | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 – 60 | |||
| Storage Temperature (°C) | 0 – 45 | |||
| Weight (kg) | 53 | 60 | 91 | 121 |
| Size (LxWxH)mm | 540x375x261 | 400x475x269 | 683x450x258 | 895x450x235 |
| Communication | RS485 | |||
| Connector | Through Wall Connector | |||
| IP Protection | IP20 | |||
| Scalability | Up to 16 units in parallel | |||
| Display | LCD Display | |||
| Warranty | 5 Years | |||
| Installation Type | Ground Mount | |||
| Parameter | 2000VA/25.6 | 3000VA/25.6 |
|---|---|---|
| Nominal DC Voltage (V) | 25.6 | 25.6 |
| MPPT Charger | ||
| Type of Charger | MPPT | MPPT |
| No of MPPT Channels | 1 | 1 |
| Max. Connected PV Modules (kW) | 2.2 | 3 |
| Max MPPT Output Current (A) | 70 | 100 |
| Max. Open Circuit PV Voltage (V) | 110 | |
| MPPT Voltage Range (V) | 35-88 | |
| MPPT Peak Efficiency | >94% | >92% |
| Solar Inverter | ||
| Input Power at Peak Load (W) | 2200 | 3000 |
| Nominal Output Voltage (V) | 220 | |
| Nominal Output Frequency (Hz) | 50 | |
| Output Supply Phase | Single Phase | |
| Overloads | 100-125%-120Sec 126-150%-60Sec 151-200% - 5 Sec >200% - Immediate | |
| Output Type | Pure Sine Wave | |
| Input Source | PV/Battery/Grid | |
| Peak Inverter Efficiency | >85% | |
| THD | >5% | |
| Load Power Factor | 0.8 | |
| Battery | ||
| Battery (Ah)/Voltage (V) | 100/25.6 | |
| Battery (Wh) | 2560 | |
| Charging Current (A) | 30 | |
| Discharging Current (A) | 50 | |
| Max Continuous Discharging Current (A) | 100 | |
| Battery Under Cut Alarm (V) | 24.2 (Settable) | |
| Battery Under Cut (V) | 24 (Settable) | |
| Float Charging Voltage (V) | 28.8 | |
| Boost Charging Voltage (V) | 28.8 | |
| Grid Charger | ||
| Grid Operating Voltage Range (V) | 120-280 | |
| Grid Frequency Range | 47-53 | |
| Ambient Conditions | ||
| Operating Temp (°C) | 0-50 | |
| Humidity | 95% | |
| Degree of Protection | IP20 | |
| Cooling Method | Temp. controlled fan cooled | |
| Display/Indication | ||
| Protections | Pv: Reverse polarity, high current Battery: Reverse polarity, under voltage cut, over voltage cut Grid: Over/under voltage, over/under freq., Surge protection, reverse feed protection Load: Overload, short circuit | |
| Display Parameters | Pv: Voltage, amps, power, today kwh, total kwh generation. Battery: Voltage, amps, charge/ discharge status Grid: Voltage, frequency., Load: voltage, load%, frequency. Load: Operating modes (ups/ wide range), priority selection, grid charging enable/ disable, battery status (charging/ discharging) | |
| Display Faults | PV: PV over voltage Battery: Battery under voltage, battery over voltage Grid: Back feed, under/ over voltage, fuse fail Load: Overload, o/p short circuit | |
| Parameter | 900VA/12.8V (WM) | 1100VA/12.8V (WM) | 1600VA/25.6V (WM) | 2000VA/25.6V (WM) |
|---|---|---|---|---|
| Nominal DC Voltage | 12.8 | 12.8 | 25.6 | 25.6 |
| MPPT Charger | ||||
| Type of Charger | MPPT | |||
| No of MPPT Channels | 1 | |||
| Max. Connected PV Modules kW | 1 | 1 | 2 | 2 |
| Max MPPT Output Current/Max Battery Charging Current (A) | 55 | |||
| Max. Open Circuit PV Voltage (V) | 50 | 50 | 100 | 100 |
| MPPT Voltage Range (V) | 30-50 | 30-50 | 40-100 | 40-100 |
| MPPT Peak Efficiency | >92% | |||
| Solar Inverter | ||||
| Input Power at Peak Load (W) | 900 | 1100 | 1600 | 2000 |
| Nominal Output Voltage (V) | 220 | |||
| Nominal Output Frequency (Hz) | 50 | |||
| Output Supply Phase | Single Phase | |||
| Overloads | 100-105% - 60Sec / 105-110% - 30Sec / 110-120% - 2 Sec | |||
| Output Type | Pure Sine Wave | |||
| Input Source | PV/Battery/Grid | |||
| Peak Inverter Efficiency | >82% | |||
| THD | >4% | |||
| Load Power Factor | 0.8 | |||
| Battery | ||||
| Battery (Ah)/Voltage (V) | 100/12.8 | 100/12.8 | 100/25.6 | 100/25.6 |
| Battery (Wh) | 1280 | 1280 | 2560 | 2560 |
| Charging Current (A) | 30 | |||
| Discharging Current (A) | 50 | |||
| Max Continuous Discharging Current (A) | 100 | |||
| Battery Under Cut Alarm (V) | 24.2 (settable) | |||
| Battery Under Cut (V) | 24 (settable) | |||
| Float Charging Voltage (V) | 28.8 | |||
| Boost Charging Voltage (V) | 28.8 | |||
| Grid Charger | ||||
| Grid Operating Voltage Range (V) | 90-280 | |||
| Grid Frequency Range | 47-53 | |||
| Display/Indication | ||||
| Protections | PV: Reverse Polarity, High Current | |||
| Display Parameters | PV: Voltage, Amps, Power, Today kWh, Total kWh Generation. | |||
| Display Faults | PV: PV over voltage | |||
| Others | ||||
| Operating Temp (°C) | 0-50 | |||
| Humidity | 0.9 | |||
| Degree of Protection | IP31 | |||
| Cooling Method | Temp. controlled natural air cooling | |||
| Dimensions (LWH) and Weight | 440x380x160mm 25kg approx. | 440x380x160mm 25kg approx. | 570x440x220mm 41kg approx. | 570x440x220mm 41kg approx. |
| Parameter | 900VA/12.8V (WM) | 1100VA/12.8V (WM) | 1600VA/25.6V (WM) | 2000VA/25.6V (WM) |
|---|---|---|---|---|
| Nominal DC Voltage | 12.8 | 12.8 | 25.6 | 25.6 |
| MPPT Charger | ||||
| Type of Charger | MPPT | |||
| No of MPPT Channels | 1 | |||
| Max. Connected PV Modules kW | 1 | 1 | 2 | 2 |
| Max MPPT Output Current/Max Battery Charging Current (A) | 55 | |||
| Max. Open Circuit PV Voltage (V) | 50 | 50 | 100 | 100 |
| MPPT Voltage Range (V) | 30-50 | 30-50 | 40-100 | 40-100 |
| MPPT Peak Efficiency | >92% | |||
| Solar Inverter | ||||
| Input Power at Peak Load (W) | 900 | 1100 | 1600 | 2000 |
| Nominal Output Voltage (V) | 220 | |||
| Nominal Output Frequency (Hz) | 50 | |||
| Output Supply Phase | Single Phase | |||
| Overloads | 100-105% - 60Sec / 105-110% - 30Sec / 110-120% - 2 Sec | |||
| Output Type | Pure Sine Wave | |||
| Input Source | PV/Battery/Grid | |||
| Peak Inverter Efficiency | >82% | |||
| THD | >4% | |||
| Load Power Factor | 0.8 | |||
| Battery | ||||
| Battery (Ah)/Voltage (V) | 100/12.8 | 100/12.8 | 100/25.6 | 100/25.6 |
| Battery (Wh) | 1280 | 1280 | 2560 | 2560 |
| Charging Current (A) | 30 | |||
| Discharging Current (A) | 50 | |||
| Max Continuous Discharging Current (A) | 100 | |||
| Battery Under Cut Alarm (V) | 24.2 (settable) | |||
| Battery Under Cut (V) | 24 (settable) | |||
| Float Charging Voltage (V) | 28.8 | |||
| Boost Charging Voltage (V) | 28.8 | |||
| Grid Charger | ||||
| Grid Operating Voltage Range (V) | 90-280 | |||
| Grid Frequency Range | 47-53 | |||
| Display/Indication | ||||
| Protections | PV: Reverse Polarity, High Current | |||
| Display Parameters | PV: Voltage, Amps, Power, Today kWh, Total kWh Generation. | |||
| Display Faults | PV: PV over voltage | |||
| Others | ||||
| Operating Temp (°C) | 0-50 | |||
| Humidity | 0.9 | |||
| Degree of Protection | IP31 | |||
| Cooling Method | Temp. controlled natural air cooling | |||
| Dimensions (LWH) and Weight | 440x380x160mm 25kg approx. | 440x380x160mm 25kg approx. | 570x440x220mm 41kg approx. | 570x440x220mm 41kg approx. |
| Parameter | 900VA/12.8V (WM) | 1100VA/12.8V (WM) | 1600VA/25.6V (WM) | 2000VA/25.6V (WM) |
|---|---|---|---|---|
| Nominal DC Voltage | 12.8 | 12.8 | 25.6 | 25.6 |
| MPPT Charger | ||||
| Type of Charger | MPPT | |||
| No of MPPT Channels | 1 | |||
| Max. Connected PV Modules kW | 1 | 1 | 2 | 2 |
| Max MPPT Output Current/Max Battery Charging Current (A) | 55 | |||
| Max. Open Circuit PV Voltage (V) | 50 | 50 | 100 | 100 |
| MPPT Voltage Range (V) | 30-50 | 30-50 | 40-100 | 40-100 |
| MPPT Peak Efficiency | >92% | |||
| Solar Inverter | ||||
| Input Power at Peak Load (W) | 900 | 1100 | 1600 | 2000 |
| Nominal Output Voltage (V) | 220 | |||
| Nominal Output Frequency (Hz) | 50 | |||
| Output Supply Phase | Single Phase | |||
| Overloads | 100-105% - 60Sec / 105-110% - 30Sec / 110-120% - 2 Sec | |||
| Output Type | Pure Sine Wave | |||
| Input Source | PV/Battery/Grid | |||
| Peak Inverter Efficiency | >82% | |||
| THD | >4% | |||
| Load Power Factor | 0.8 | |||
| Battery | ||||
| Battery (Ah)/Voltage (V) | 100/12.8 | 100/12.8 | 100/25.6 | 100/25.6 |
| Battery (Wh) | 1280 | 1280 | 2560 | 2560 |
| Charging Current (A) | 30 | |||
| Discharging Current (A) | 50 | |||
| Max Continuous Discharging Current (A) | 100 | |||
| Battery Under Cut Alarm (V) | 24.2 (settable) | |||
| Battery Under Cut (V) | 24 (settable) | |||
| Float Charging Voltage (V) | 28.8 | |||
| Boost Charging Voltage (V) | 28.8 | |||
| Grid Charger | ||||
| Grid Operating Voltage Range (V) | 90-280 | |||
| Grid Frequency Range | 47-53 | |||
| Display/Indication | ||||
| Protections | PV: Reverse Polarity, High Current | |||
| Display Parameters | PV: Voltage, Amps, Power, Today kWh, Total kWh Generation. | |||
| Display Faults | PV: PV over voltage | |||
| Others | ||||
| Operating Temp (°C) | 0-50 | |||
| Humidity | 0.9 | |||
| Degree of Protection | IP31 | |||
| Cooling Method | Temp. controlled natural air cooling | |||
| Dimensions (LWH) and Weight | 440x380x160mm 25kg approx. | 440x380x160mm 25kg approx. | 570x440x220mm 41kg approx. | 570x440x220mm 41kg approx. |
| Parameter | 900VA/12.8V (WM) | 1100VA/12.8V (WM) | 1600VA/25.6V (WM) | 2000VA/25.6V (WM) |
|---|---|---|---|---|
| Nominal DC Voltage | 12.8 | 12.8 | 25.6 | 25.6 |
| MPPT Charger | ||||
| Type of Charger | MPPT | |||
| No of MPPT Channels | 1 | |||
| Max. Connected PV Modules kW | 1 | 1 | 2 | 2 |
| Max MPPT Output Current/Max Battery Charging Current (A) | 55 | |||
| Max. Open Circuit PV Voltage (V) | 50 | 50 | 100 | 100 |
| MPPT Voltage Range (V) | 30-50 | 30-50 | 40-100 | 40-100 |
| MPPT Peak Efficiency | >92% | |||
| Solar Inverter | ||||
| Input Power at Peak Load (W) | 900 | 1100 | 1600 | 2000 |
| Nominal Output Voltage (V) | 220 | |||
| Nominal Output Frequency (Hz) | 50 | |||
| Output Supply Phase | Single Phase | |||
| Overloads | 100-105% - 60Sec / 105-110% - 30Sec / 110-120% - 2 Sec | |||
| Output Type | Pure Sine Wave | |||
| Input Source | PV/Battery/Grid | |||
| Peak Inverter Efficiency | >82% | |||
| THD | >4% | |||
| Load Power Factor | 0.8 | |||
| Battery | ||||
| Battery (Ah)/Voltage (V) | 100/12.8 | 100/12.8 | 100/25.6 | 100/25.6 |
| Battery (Wh) | 1280 | 1280 | 2560 | 2560 |
| Charging Current (A) | 30 | |||
| Discharging Current (A) | 50 | |||
| Max Continuous Discharging Current (A) | 100 | |||
| Battery Under Cut Alarm (V) | 24.2 (settable) | |||
| Battery Under Cut (V) | 24 (settable) | |||
| Float Charging Voltage (V) | 28.8 | |||
| Boost Charging Voltage (V) | 28.8 | |||
| Grid Charger | ||||
| Grid Operating Voltage Range (V) | 90-280 | |||
| Grid Frequency Range | 47-53 | |||
| Display/Indication | ||||
| Protections | PV: Reverse Polarity, High Current | |||
| Display Parameters | PV: Voltage, Amps, Power, Today kWh, Total kWh Generation. | |||
| Display Faults | PV: PV over voltage | |||
| Others | ||||
| Operating Temp (°C) | 0-50 | |||
| Humidity | 0.9 | |||
| Degree of Protection | IP31 | |||
| Cooling Method | Temp. controlled natural air cooling | |||
| Dimensions (LWH) and Weight | 440x380x160mm 25kg approx. | 440x380x160mm 25kg approx. | 570x440x220mm 41kg approx. | 570x440x220mm 41kg approx. |
| Parameter | 2000VA/25.6 | 3000VA/25.6 |
|---|---|---|
| Nominal DC Voltage (V) | 25.6 | 25.6 |
| MPPT Charger | ||
| Type of Charger | MPPT | MPPT |
| No of MPPT Channels | 1 | 1 |
| Max. Connected PV Modules (kW) | 2.2 | 3 |
| Max MPPT Output Current (A) | 70 | 100 |
| Max. Open Circuit PV Voltage (V) | 110 | |
| MPPT Voltage Range (V) | 35-88 | |
| MPPT Peak Efficiency | >94% | >92% |
| Solar Inverter | ||
| Input Power at Peak Load (W) | 2200 | 3000 |
| Nominal Output Voltage (V) | 220 | |
| Nominal Output Frequency (Hz) | 50 | |
| Output Supply Phase | Single Phase | |
| Overloads | 100-125%-120Sec 126-150%-60Sec 151-200% - 5 Sec >200% - Immediate | |
| Output Type | Pure Sine Wave | |
| Input Source | PV/Battery/Grid | |
| Peak Inverter Efficiency | >85% | |
| THD | >5% | |
| Load Power Factor | 0.8 | |
| Battery | ||
| Battery (Ah)/Voltage (V) | 100/25.6 | |
| Battery (Wh) | 2560 | |
| Charging Current (A) | 30 | |
| Discharging Current (A) | 50 | |
| Max Continuous Discharging Current (A) | 100 | |
| Battery Under Cut Alarm (V) | 24.2 (Settable) | |
| Battery Under Cut (V) | 24 (Settable) | |
| Float Charging Voltage (V) | 28.8 | |
| Boost Charging Voltage (V) | 28.8 | |
| Grid Charger | ||
| Grid Operating Voltage Range (V) | 120-280 | |
| Grid Frequency Range | 47-53 | |
| Ambient Conditions | ||
| Operating Temp (°C) | 0-50 | |
| Humidity | 95% | |
| Degree of Protection | IP20 | |
| Cooling Method | Temp. controlled fan cooled | |
| Display/Indication | ||
| Protections | Pv: Reverse polarity, high current Battery: Reverse polarity, under voltage cut, over voltage cut Grid: Over/under voltage, over/under freq., Surge protection, reverse feed protection Load: Overload, short circuit | |
| Display Parameters | Pv: Voltage, amps, power, today kwh, total kwh generation. Battery: Voltage, amps, charge/ discharge status Grid: Voltage, frequency., Load: voltage, load%, frequency. Load: Operating modes (ups/ wide range), priority selection, grid charging enable/ disable, battery status (charging/ discharging) | |
| Display Faults | PV: PV over voltage Battery: Battery under voltage, battery over voltage Grid: Back feed, under/ over voltage, fuse fail Load: Overload, o/p short circuit | |
| Parameter | 5kW / 51.2V / 1P | 5kW / 51.2V / 1P | 5kW / 51.2V / 1P |
|---|---|---|---|
| Storage Capacity Range | 10kWh | 15kWh | 20kWh |
| Battery Type | LiFePO4 | ||
| BMS | Active BMS Inbuilt | ||
| Max Charge/Discharge Rate | 0.5C / 1C Rate | ||
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | ||
| MPPT Topology | Buck Type | ||
| Input PV Capacity (in kW) | Same as Inverter Capacity | ||
| Max Open Circuit Voltage (Voc) | 190V DC | ||
| MPPT Input Range (Vmp) | 75 - 160V DC | ||
| MPPT Efficiency | 95% | ||
| Inverter Type | Hybrid with Grid Export Features | ||
| Output Voltage (Standalone) | 230VAC +/- 2% | ||
| Output Frequency (Standalone) | 50Hz +/- 2% | ||
| Overload (60sec | 30sec | 5sec) | 101-110% | 111-125% | 126-150% | ||
| Grid Input Voltage | 230VAC +10% & -20% | ||
| Phase / Connection | 1 Phase / 2 Wire | ||
| Display Interface | Graphical LCD with backlight | ||
| LED Indications | Mains On, Alarm, Buzzer Mute | ||
| PV Side | Reverse Polarity, PV Power limit, MOV | ||
| Battery Side | Reverse Polarity, Over/Under Voltage | ||
| Grid Side | Over/Under Voltage, Frequency, MOV | ||
| Degree of Protection | IP 21 | ||
| Environment Temperature | 0 to 50°C (Rec: 0 to 40°C) | ||
| Footprint Dimensions (mm) | 650 * 630 | ||
| Parameter | 5kW / 51.2V / 1P | 5kW / 51.2V / 1P | 5kW / 51.2V / 1P |
|---|---|---|---|
| Storage Capacity Range | 10kWh | 15kWh | 20kWh |
| Battery Type | LiFePO4 | ||
| BMS | Active BMS Inbuilt | ||
| Max Charge/Discharge Rate | 0.5C / 1C Rate | ||
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | ||
| MPPT Topology | Buck Type | ||
| Input PV Capacity (in kW) | Same as Inverter Capacity | ||
| Max Open Circuit Voltage (Voc) | 190V DC | ||
| MPPT Input Range (Vmp) | 75 - 160V DC | ||
| MPPT Efficiency | 95% | ||
| Inverter Type | Hybrid with Grid Export Features | ||
| Output Voltage (Standalone) | 230VAC +/- 2% | ||
| Output Frequency (Standalone) | 50Hz +/- 2% | ||
| Overload (60sec | 30sec | 5sec) | 101-110% | 111-125% | 126-150% | ||
| Grid Input Voltage | 230VAC +10% & -20% | ||
| Phase / Connection | 1 Phase / 2 Wire | ||
| Display Interface | Graphical LCD with backlight | ||
| LED Indications | Mains On, Alarm, Buzzer Mute | ||
| PV Side | Reverse Polarity, PV Power limit, MOV | ||
| Battery Side | Reverse Polarity, Over/Under Voltage | ||
| Grid Side | Over/Under Voltage, Frequency, MOV | ||
| Degree of Protection | IP 21 | ||
| Environment Temperature | 0 to 50°C (Rec: 0 to 40°C) | ||
| Footprint Dimensions (mm) | 650 * 630 | ||
| Parameter | 5kW / 51.2V / 1P | 5kW / 51.2V / 1P | 5kW / 51.2V / 1P |
|---|---|---|---|
| Storage Capacity Range | 10kWh | 15kWh | 20kWh |
| Battery Type | LiFePO4 | ||
| BMS | Active BMS Inbuilt | ||
| Max Charge/Discharge Rate | 0.5C / 1C Rate | ||
| Cycle Life (95% DOD, 25°C, 0.5C/0.5C) | 6000 | ||
| MPPT Topology | Buck Type | ||
| Input PV Capacity (in kW) | Same as Inverter Capacity | ||
| Max Open Circuit Voltage (Voc) | 190V DC | ||
| MPPT Input Range (Vmp) | 75 - 160V DC | ||
| MPPT Efficiency | 95% | ||
| Inverter Type | Hybrid with Grid Export Features | ||
| Output Voltage (Standalone) | 230VAC +/- 2% | ||
| Output Frequency (Standalone) | 50Hz +/- 2% | ||
| Overload (60sec | 30sec | 5sec) | 101-110% | 111-125% | 126-150% | ||
| Grid Input Voltage | 230VAC +10% & -20% | ||
| Phase / Connection | 1 Phase / 2 Wire | ||
| Display Interface | Graphical LCD with backlight | ||
| LED Indications | Mains On, Alarm, Buzzer Mute | ||
| PV Side | Reverse Polarity, PV Power limit, MOV | ||
| Battery Side | Reverse Polarity, Over/Under Voltage | ||
| Grid Side | Over/Under Voltage, Frequency, MOV | ||
| Degree of Protection | IP 21 | ||
| Environment Temperature | 0 to 50°C (Rec: 0 to 40°C) | ||
| Footprint Dimensions (mm) | 650 * 630 | ||
| Parameter | 48V 100Ah | 48V 200Ah | 48V 300Ah | 48V 400Ah |
|---|---|---|---|---|
| Battery Capacity(kWh) | 4.8 | 9.6 | 14.4 | 19.2 |
| Nominal Voltage (V) | 48V | |||
| Capacity (Ah) | 100 | 200 | 300 | 400 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 54 (±1.5) | |||
| Minimum cut-off voltage (V) | 42 (±1.5) | |||
| Charging Voltage (V) | 52.5 | |||
| Recommended Charging Current (A) | 30 | 60 | 90 | 120 |
| Maximum Charging Current (A) | 50 | 100 | 150 | 200 |
| Recommended Discharge Current (A) | 50 | 100 | 150 | 200 |
| Maximum Discharging Current (A) | 100 | 200 | 300 | 400 |
| Cycle Life | 6000 (95% DOD, 25°C, 0.5C/0.5C) | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 - 60 | |||
| Storage Temperature (°C) | 0 - 45 | |||
| Communication Interface/Protocol | RS485 | |||
| Connector | Through Wall Connector | |||
| Standards (Compliance) | UN38.3, IEC 62619, IEC 61000, UL 1973 | |||
| Protection | Over voltage, under-voltage Over-temperature (charge and discharge) Under-temperature (charge and discharge) Over current (charge and discharge) External short circuit detection | |||
| IP Protection | IP 20 | |||
| Parameter | 48V 100Ah | 48V 200Ah | 48V 300Ah | 48V 400Ah |
|---|---|---|---|---|
| Battery Capacity(kWh) | 4.8 | 9.6 | 14.4 | 19.2 |
| Nominal Voltage (V) | 48V | |||
| Capacity (Ah) | 100 | 200 | 300 | 400 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 54 (±1.5) | |||
| Minimum cut-off voltage (V) | 42 (±1.5) | |||
| Charging Voltage (V) | 52.5 | |||
| Recommended Charging Current (A) | 30 | 60 | 90 | 120 |
| Maximum Charging Current (A) | 50 | 100 | 150 | 200 |
| Recommended Discharge Current (A) | 50 | 100 | 150 | 200 |
| Maximum Discharging Current (A) | 100 | 200 | 300 | 400 |
| Cycle Life | 6000 (95% DOD, 25°C, 0.5C/0.5C) | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 - 60 | |||
| Storage Temperature (°C) | 0 - 45 | |||
| Communication Interface/Protocol | RS485 | |||
| Connector | Through Wall Connector | |||
| Standards (Compliance) | UN38.3, IEC 62619, IEC 61000, UL 1973 | |||
| Protection | Over voltage, under-voltage Over-temperature (charge and discharge) Under-temperature (charge and discharge) Over current (charge and discharge) External short circuit detection | |||
| IP Protection | IP 20 | |||
| Parameter | 48V 100Ah | 48V 200Ah | 48V 300Ah | 48V 400Ah |
|---|---|---|---|---|
| Battery Capacity(kWh) | 4.8 | 9.6 | 14.4 | 19.2 |
| Nominal Voltage (V) | 48V | |||
| Capacity (Ah) | 100 | 200 | 300 | 400 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 54 (±1.5) | |||
| Minimum cut-off voltage (V) | 42 (±1.5) | |||
| Charging Voltage (V) | 52.5 | |||
| Recommended Charging Current (A) | 30 | 60 | 90 | 120 |
| Maximum Charging Current (A) | 50 | 100 | 150 | 200 |
| Recommended Discharge Current (A) | 50 | 100 | 150 | 200 |
| Maximum Discharging Current (A) | 100 | 200 | 300 | 400 |
| Cycle Life | 6000 (95% DOD, 25°C, 0.5C/0.5C) | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 - 60 | |||
| Storage Temperature (°C) | 0 - 45 | |||
| Communication Interface/Protocol | RS485 | |||
| Connector | Through Wall Connector | |||
| Standards (Compliance) | UN38.3, IEC 62619, IEC 61000, UL 1973 | |||
| Protection | Over voltage, under-voltage Over-temperature (charge and discharge) Under-temperature (charge and discharge) Over current (charge and discharge) External short circuit detection | |||
| IP Protection | IP 20 | |||
| Parameter | 48V 100Ah | 48V 200Ah | 48V 300Ah | 48V 400Ah |
|---|---|---|---|---|
| Battery Capacity(kWh) | 4.8 | 9.6 | 14.4 | 19.2 |
| Nominal Voltage (V) | 48V | |||
| Capacity (Ah) | 100 | 200 | 300 | 400 |
| Cell Type and Chemistry | Prismatic, LFP | |||
| BMS Type | Smart | |||
| Maximum cut-off voltage (V) | 54 (±1.5) | |||
| Minimum cut-off voltage (V) | 42 (±1.5) | |||
| Charging Voltage (V) | 52.5 | |||
| Recommended Charging Current (A) | 30 | 60 | 90 | 120 |
| Maximum Charging Current (A) | 50 | 100 | 150 | 200 |
| Recommended Discharge Current (A) | 50 | 100 | 150 | 200 |
| Maximum Discharging Current (A) | 100 | 200 | 300 | 400 |
| Cycle Life | 6000 (95% DOD, 25°C, 0.5C/0.5C) | |||
| Cell under voltage protection | Yes | |||
| Cell over voltage Protection | Yes | |||
| Over current protection | Yes | |||
| Short circuit protection | Yes | |||
| Temperature protection | Yes | |||
| Working Temperature (°C) | 0 - 60 | |||
| Storage Temperature (°C) | 0 - 45 | |||
| Communication Interface/Protocol | RS485 | |||
| Connector | Through Wall Connector | |||
| Standards (Compliance) | UN38.3, IEC 62619, IEC 61000, UL 1973 | |||
| Protection | Over voltage, under-voltage Over-temperature (charge and discharge) Under-temperature (charge and discharge) Over current (charge and discharge) External short circuit detection | |||
| IP Protection | IP 20 | |||
| Parameter | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
|---|---|---|---|---|---|---|
| PV String Input Data | ||||||
| Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
| Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
| Start-up Voltage (V) | 80 | |||||
| MPPT Voltage Range (Vdc) | 70-500 | |||||
| Rated PV Input Voltage (V) | 360 | 420 | ||||
| Max. Operating PV Input Current (A) | 20 | |||||
| Max. Input Short Circuit Current (A) | 30 | |||||
| No. of MPPT Trackers/No. of Strings MPPT Tracker | 1 / 1 | |||||
| AC Output Side | ||||||
| Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
| Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 15/14.4 | 20/19.2 | 25/24 |
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||
| Grid Connection Form | L/N/PE | |||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||
| Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
| Total Current Harmonic Distortion THDi | <3% | |||||
| DC Injection Current | <0.5% ln | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.50% | |||||
| Euro Efficiency | 97.00% | |||||
| MPPT Efficiency | >99% | |||||
| Equipment Protection | ||||||
| DC Polarity Reverse Connection Protection | YES | |||||
| Thermal Protection | YES | |||||
| Earth Fault Detection | YES | |||||
| Over voltage Load Drop Protection | YES | |||||
| Residual Current (RCD) Detection | YES | |||||
| Interface | ||||||
| Communication Interface | RS485/RS232 | |||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||
| General Data | ||||||
| Operating Temperature Range (°C) | (-10 to +60, >45 De-rating) | |||||
| Permissible Ambient Humidity | 0-100% | |||||
| Permissible Altitude (m) | 4000 | |||||
| Ingress Protection(IP) Rating | IP65 | |||||
| Inverter Topology | Non-isolated | |||||
| Type of Cooling | Natural cooling | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE- Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| Certificates | BIS Certified | |||||
| Parameter | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
|---|---|---|---|---|---|---|
| PV String Input Data | ||||||
| Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
| Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
| Start-up Voltage (V) | 80 | |||||
| MPPT Voltage Range (Vdc) | 70-500 | |||||
| Rated PV Input Voltage (V) | 360 | 420 | ||||
| Max. Operating PV Input Current (A) | 20 | |||||
| Max. Input Short Circuit Current (A) | 30 | |||||
| No. of MPPT Trackers/No. of Strings MPPT Tracker | 1 / 1 | |||||
| AC Output Side | ||||||
| Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
| Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 15/14.4 | 20/19.2 | 25/24 |
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||
| Grid Connection Form | L/N/PE | |||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||
| Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
| Total Current Harmonic Distortion THDi | <3% | |||||
| DC Injection Current | <0.5% ln | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.50% | |||||
| Euro Efficiency | 97.00% | |||||
| MPPT Efficiency | >99% | |||||
| Equipment Protection | ||||||
| DC Polarity Reverse Connection Protection | YES | |||||
| Thermal Protection | YES | |||||
| Earth Fault Detection | YES | |||||
| Over voltage Load Drop Protection | YES | |||||
| Residual Current (RCD) Detection | YES | |||||
| Interface | ||||||
| Communication Interface | RS485/RS232 | |||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||
| General Data | ||||||
| Operating Temperature Range (°C) | (-10 to +60, >45 De-rating) | |||||
| Permissible Ambient Humidity | 0-100% | |||||
| Permissible Altitude (m) | 4000 | |||||
| Ingress Protection(IP) Rating | IP65 | |||||
| Inverter Topology | Non-isolated | |||||
| Type of Cooling | Natural cooling | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE- Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| Certificates | BIS Certified | |||||
| Parameter | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
|---|---|---|---|---|---|---|
| PV String Input Data | ||||||
| Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
| Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
| Start-up Voltage (V) | 80 | |||||
| MPPT Voltage Range (Vdc) | 70-500 | |||||
| Rated PV Input Voltage (V) | 360 | 420 | ||||
| Max. Operating PV Input Current (A) | 20 | |||||
| Max. Input Short Circuit Current (A) | 30 | |||||
| No. of MPPT Trackers/No. of Strings MPPT Tracker | 1 / 1 | |||||
| AC Output Side | ||||||
| Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
| Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 15/14.4 | 20/19.2 | 25/24 |
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||
| Grid Connection Form | L/N/PE | |||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||
| Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
| Total Current Harmonic Distortion THDi | <3% | |||||
| DC Injection Current | <0.5% ln | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.50% | |||||
| Euro Efficiency | 97.00% | |||||
| MPPT Efficiency | >99% | |||||
| Equipment Protection | ||||||
| DC Polarity Reverse Connection Protection | YES | |||||
| Thermal Protection | YES | |||||
| Earth Fault Detection | YES | |||||
| Over voltage Load Drop Protection | YES | |||||
| Residual Current (RCD) Detection | YES | |||||
| Interface | ||||||
| Communication Interface | RS485/RS232 | |||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||
| General Data | ||||||
| Operating Temperature Range (°C) | (-10 to +60, >45 De-rating) | |||||
| Permissible Ambient Humidity | 0-100% | |||||
| Permissible Altitude (m) | 4000 | |||||
| Ingress Protection(IP) Rating | IP65 | |||||
| Inverter Topology | Non-isolated | |||||
| Type of Cooling | Natural cooling | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE- Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| Certificates | BIS Certified | |||||
| Parameter | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
|---|---|---|---|---|---|---|
| PV String Input Data | ||||||
| Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
| Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
| Start-up Voltage (V) | 80 | |||||
| MPPT Voltage Range (Vdc) | 70-500 | |||||
| Rated PV Input Voltage (V) | 360 | 420 | ||||
| Max. Operating PV Input Current (A) | 20 | |||||
| Max. Input Short Circuit Current (A) | 30 | |||||
| No. of MPPT Trackers/No. of Strings MPPT Tracker | 1 / 1 | |||||
| AC Output Side | ||||||
| Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
| Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 15/14.4 | 20/19.2 | 25/24 |
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||
| Grid Connection Form | L/N/PE | |||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||
| Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
| Total Current Harmonic Distortion THDi | <3% | |||||
| DC Injection Current | <0.5% ln | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.50% | |||||
| Euro Efficiency | 97.00% | |||||
| MPPT Efficiency | >99% | |||||
| Equipment Protection | ||||||
| DC Polarity Reverse Connection Protection | YES | |||||
| Thermal Protection | YES | |||||
| Earth Fault Detection | YES | |||||
| Over voltage Load Drop Protection | YES | |||||
| Residual Current (RCD) Detection | YES | |||||
| Interface | ||||||
| Communication Interface | RS485/RS232 | |||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||
| General Data | ||||||
| Operating Temperature Range (°C) | (-10 to +60, >45 De-rating) | |||||
| Permissible Ambient Humidity | 0-100% | |||||
| Permissible Altitude (m) | 4000 | |||||
| Ingress Protection(IP) Rating | IP65 | |||||
| Inverter Topology | Non-isolated | |||||
| Type of Cooling | Natural cooling | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE- Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| Certificates | BIS Certified | |||||
| Parameter | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
|---|---|---|---|---|---|---|
| PV String Input Data | ||||||
| Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
| Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
| Start-up Voltage (V) | 80 | |||||
| MPPT Voltage Range (Vdc) | 70-500 | |||||
| Rated PV Input Voltage (V) | 360 | 420 | ||||
| Max. Operating PV Input Current (A) | 20 | |||||
| Max. Input Short Circuit Current (A) | 30 | |||||
| No. of MPPT Trackers/No. of Strings MPPT Tracker | 1 / 1 | |||||
| AC Output Side | ||||||
| Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
| Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 15/14.4 | 20/19.2 | 25/24 |
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||
| Grid Connection Form | L/N/PE | |||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||
| Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
| Total Current Harmonic Distortion THDi | <3% | |||||
| DC Injection Current | <0.5% ln | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.50% | |||||
| Euro Efficiency | 97.00% | |||||
| MPPT Efficiency | >99% | |||||
| Equipment Protection | ||||||
| DC Polarity Reverse Connection Protection | YES | |||||
| Thermal Protection | YES | |||||
| Earth Fault Detection | YES | |||||
| Over voltage Load Drop Protection | YES | |||||
| Residual Current (RCD) Detection | YES | |||||
| Interface | ||||||
| Communication Interface | RS485/RS232 | |||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||
| General Data | ||||||
| Operating Temperature Range (°C) | (-10 to +60, >45 De-rating) | |||||
| Permissible Ambient Humidity | 0-100% | |||||
| Permissible Altitude (m) | 4000 | |||||
| Ingress Protection(IP) Rating | IP65 | |||||
| Inverter Topology | Non-isolated | |||||
| Type of Cooling | Natural cooling | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE- Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| Certificates | BIS Certified | |||||
| Parameter | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
|---|---|---|---|---|---|---|
| PV String Input Data | ||||||
| Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
| Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
| Start-up Voltage (V) | 80 | |||||
| MPPT Voltage Range (Vdc) | 70-500 | |||||
| Rated PV Input Voltage (V) | 360 | 420 | ||||
| Max. Operating PV Input Current (A) | 20 | |||||
| Max. Input Short Circuit Current (A) | 30 | |||||
| No. of MPPT Trackers/No. of Strings MPPT Tracker | 1 / 1 | |||||
| AC Output Side | ||||||
| Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
| Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 15/14.4 | 20/19.2 | 25/24 |
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||
| Grid Connection Form | L/N/PE | |||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||
| Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
| Total Current Harmonic Distortion THDi | <3% | |||||
| DC Injection Current | <0.5% ln | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.50% | |||||
| Euro Efficiency | 97.00% | |||||
| MPPT Efficiency | >99% | |||||
| Equipment Protection | ||||||
| DC Polarity Reverse Connection Protection | YES | |||||
| Thermal Protection | YES | |||||
| Earth Fault Detection | YES | |||||
| Over voltage Load Drop Protection | YES | |||||
| Residual Current (RCD) Detection | YES | |||||
| Interface | ||||||
| Communication Interface | RS485/RS232 | |||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||
| General Data | ||||||
| Operating Temperature Range (°C) | (-10 to +60, >45 De-rating) | |||||
| Permissible Ambient Humidity | 0-100% | |||||
| Permissible Altitude (m) | 4000 | |||||
| Ingress Protection(IP) Rating | IP65 | |||||
| Inverter Topology | Non-isolated | |||||
| Type of Cooling | Natural cooling | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE- Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| Certificates | BIS Certified | |||||
Retro fitting refers to the ability to integrate our inverter battery system with existing inverters, allowing seamless upgrades without the need to replace your current system.
You can power a variety of household appliances, including Lights, fans, routers, and laptops, TVs, refrigerators, and water purifiers. Some models may also support heavier appliances, depending on the inverter and battery capacity.
Our inverter batteries outperform traditional lead-acid batteries in several ways: • Up to 3 times longer lifespan • Faster charging capabilities • Higher energy efficiency • Smart monitoring and diagnostics • Wall-mounted design for better space utilization
Yes, all CLN batteries are manufactured under ISO-certified processes and meet recognized safety and quality standards.
Please refer to the user manual provided with our inverter battery for installation and safety guidelines.
Our battery comes with a 5-year warranty in Energy storage, covering manufacturing defects under standard usage conditions.
Yes, our battery pack is designed for both home and office applications, offering reliable backup power for a variety of needs.
Backup time varies based on the connected load. Under standard usage, it typically ranges from 2 to 8 hours.
Our all-in-one system integrates the battery, inverter, and charger into a single compact unit. This design simplifies installation and provides a seamless power backup solution.
A stackable battery solution is a modular energy storage system where multiple battery units can be stacked vertically to increase overall capacity and backup time, depending on your energy requirements.
Scalability: Easily expand capacity by adding more units as your energy needs grow. Space Efficiency: Vertical stacking minimizes floor space usage. Ease of Maintenance: Simplified module replacement and system management.
Typically, 4 to 6 battery units can be stacked, depending on the system design and total power/energy requirements.
No, as long as the units are correctly connected and managed through a Battery Management System, performance remains consistent and reliable.
Stackable systems offer easy capacity expansion, a compact footprint, plug-and-play installation, and reduced wiring complexity.
Hello — how can we help you today?
Chat with us on WhatsApp Call 1800-313-6541 Send an enquiryWe have received your message.
Need to speak to someone sooner?
Request a quote
For: